System Calculator

SavedAll changes saved
Back to home page

1-click templates

Start from a proven configuration

Pick an installation type — we fill appliances, voltage, battery chemistry and run the schematic calculation.

1-click
Design steps
Mobile-first stepper. Complete each section — the live preview updates instantly.

Scales phone charging (10 W × person · 1 h/day) and lights (10 W + 10 W × person).

Inverter / voltage converter selection

Recommended inverter: 3000 W (Continuous: 2647 W, Peak: 4235 W)

Inverter operating mode

Inductive loads (2× surge): Indukční deska

Inverter idle self-consumption

40 W × 4 h/day = 160 Wh/day

Inverter no-load self-consumption (idle consumption)

Load concurrency matrix (simultaneity factor)

Concurrency OK

Concurrency factor 1 · connected 1800 W / inverter 3000 W

Sum of 230 V appliances is within continuous inverter power — unrestricted concurrent use.

Daily Consumption

1833 Wh

76.4 Ah/day

Battery Autonomy

2.4 d (57 h)

Target 2 d · 200 Ah

Max Peak Current

226.9 A

Battery bus worst-case

Wiring diagram
Interactive SVG preview with live gauge & fuse labels.
  • Battery ↔ Busbar

    50 mm² · 200 A Class T

  • Busbar ↔ Inverter

    50 mm² · 200 A Class T

  • MPPT ↔ Battery

    4 mm² · 25 A ATO

System expansion check
Optional “what if I add an appliance” check.

Enter your existing inverter rating and an appliance — see the verdict and what to change.

No — changes required
  • Inverter OK

    Existing 3000 W covers the 1200 W appliance.

  • Concurrency OK

    Sum of 230 V loads does not exceed inverter 3000 W.

  • Battery too small

    At 5 h/day you need ≥ 787 Ah (have 200 Ah, 8491 Wh/day).

After check: 8491 Wh/day · min. battery 787 Ah

Complete workshop pack & wiring schematic
Basic calculation is free. The full 5-page Wiring Blueprint unlocks the schematic, wire schedule, thermal audit, BOM and workshop labels.
Pay per export

Blueprint page preview (locked)

Cropped teasers only — full terminals, gauges and fuses unlock after purchase.

Connection schematic

2 / 5

BAT1 · FUSE · DISC · BUS
Unlock in PDF

Wire schedule From→To

3 / 5

Unlock in PDF

Premium engineering audits included in the PDF

Available in the installation blueprint

DC-DC alternator charging & idle overload protection

Full input/output sizing for voltage conversion (e.g. 12V alternator → 24V traction). Safe D+ sense wiring for Euro 6 smart alternators and idle overload protection.

Available in the installation blueprint

230 V shock protection & N-PE bonding (IEC 60364)

Inverter grounding-relay wiring and chassis ground placed after the shunt so the RCD/RCBO works without floating chassis voltage.

Available in the installation blueprint

Enclosure thermal audit & ventilation m³/h

Dynamic heat-loss sum from inverter, MPPT and DC-DC at full load (estimate: 317 W). Exact ventilation airflow in m³/h to protect cells from degradation.

Available in the installation blueprint

Global & seasonal solar analysis (4 seasons by world destination)

Detailed energy production matrix (Spring, Summer, Autumn, Winter) for the selected world destination, including southern-hemisphere calendar alignment. Battery sizing for overcast days and DC-DC booster drive-time to bridge the deficit.

Available in the installation blueprint

Workshop print pack: cable labels & CSV BOM

Cut-out cable wraps for lamination (gauge, voltage, protection) + one-click CSV BOM for material ordering.

Basic calculation (free)

  • • Indicative watts and daily balance
  • • Theoretical conductor cross-sections
  • • Simplified block diagram

Wiring Blueprint & Installation Guide (PDF + CSV)

  • • Connection diagram with terminals, gauges and fuses including DC-DC and 230 V
  • • Thermal audit and enclosure ventilation sizing
  • • Itemized BOM + wire identification labels
  • • RCBO 16 A / 30 mA Type A and N-PE bonding per IEC 60364
  • • Euro 6 smart-alternator protection (D+ / idle)
The installation blueprint provides a verified commissioning procedure per ISO 10133 and IEC 60364-7-721.

Per ISO 10133 and IEC 60364

Complete Wiring Blueprint

€12

One-time · PDF + CSV · no account needed

Payment is charged in CZK (290 Kč).

By submitting and downloading you acknowledge the informative and advisory nature of this documentation.

Instant generationSecure payment

By submitting and downloading you acknowledge the informative and advisory nature of this Technical Installation Concept.

Export Wiring Blueprint (PDF)
Download the free summary or unlock the Wiring Blueprint & Installation Guide (PDF).

Engineering Health Check

Safety audit per ISO 10133 / IEC 60364-7-721 / ABYC E-11

OK: 6 · Advisory: 2 · Hazard: 2

  • Voltage drops compliant

    Round-trip DC drop meets Victron / ISO criteria.

  • BMS discharge overload

    Peak 227 A exceeds BMS 200 A — raise voltage or parallel packs.

  • MPPT frost over-voltage

    Voc reaches 111.7 V at −15 °C, exceeding the controller limit (100 V). Use a more parallel layout or a higher MPPT Voc series.

  • Inverter thermal clearance

    Keep ≥ 100 mm free air above/below high-power inverters.

  • 230 V concurrency OK

    Sum 1800 W ≤ continuous inverter rating 3000 W.

  • Fuse coordination OK

    OCPD ≤ cable ampacity; Class-T / high-AIC MEGA for LiFePO4 (high prospective short-circuit current).

  • Battery fuse distance

    Battery↔bus run 0.50 m > ISO 10133 max 0.2 m — place Class-T ≤200 mm from + post.

  • Pre-charge resistor recommended

    Inverter 3000 W ≥ 2000 W — limit inrush into BMS FETs/contactors.

Advanced toolsCloud projects, config brief, and white-label PDF for workshops.+−

Cloud projects need Supabase configured.

System engineering audit

Algorithmic IEC / ISO standards check — deterministic safety validation from your inputs. No generative models.

24V LiFePO4 off-grid draft
Loads (4): Kompresorová lednice (DC): 60 W × 8 h/day; Indukční deska (AC): 1800 W × 0.5 h/day; Nabíjení mobilů (DC): 20 W × 1 h/day; Světla (DC): 30 W × 5 h/day
Daily energy: 1833 Wh/day (76.4 Ah)
Battery: 200 Ah LiFePO4 @ 90% DOD · target autonomy 2 d · installed autonomy ~2.4 d
Solar: 800 Wp · MPPT ≥ 23.6 A / Voc≤ 125.1 V
Peak bus current: 226.9 A
Distances: Bat↔Bus 0.5 m · Bus↔Inv 1.5 m · MPPT↔Bat 2 m
Cables: Battery ↔ Busbar: 50 mm², 200A Class T | Busbar ↔ Inverter: 50 mm², 200A Class T | MPPT ↔ Battery: 4 mm², 25A ATO

No advisories.

Complete Wiring Blueprint

€12

One-time · PDF + CSV · no account needed

Payment is charged in CZK (290 Kč).

By submitting and downloading you acknowledge the informative and advisory nature of this documentation.

VoltSchema

Professional sizing and Wiring Blueprint & Installation Guide for off-grid systems

Standards & assurance

  • Aligned with ISO 10133 and IEC 60364-7-721
  • Calculations verified against electrotechnical standards

Legal

  • Terms of service
  • Privacy policy (GDPR)
  • VoltSchema

Technical support & contact

Need help with a configuration or found a bug? Write to us at info@voltschema.com.

  • info@voltschema.com
  • Payment gatewayStripe · active (live)
© 2026 VoltSchema · All rights reserved